Solid fuel steel boiler “DYNAMIC”
Solid fuel steel boilers "DYNAMIC", complete with a mechanical thermostat and a thermometer.
Capacities: 15, 25, 35, 55 kW.
The "DYNAMIC" boilers are intended for heating residential buildings, villas, industrial buildings, ext. with heating volume up to 800 m³ and 90С max temperature of the water.
The boilers have been tested and certified and comply with the requirements of the Bulgarian State Standard EN 303-5:2001.
DESCRIPTION:
The combustion chamber has a rectangular shape, manufactured using a high quality steel.
The volume of the combustion chamber ensures 8 to 9 hours of continuous operation at one loading should there be enough fuel.
There are a number of flue pipes at the top of the combustion chamber. This would guarantee a larger heating surface, a better draught, less sooting-up, easier maintenance and maximum efficiency of 75 %.
The face of the boiler is equipped with two doors, big enough to easily load even voluminous logs or lumps of coal.
TECHNICAL DATA AND DIMENSIONS:
Type boiler |
Dynamic 15 |
Dynamic 25 |
Dynamic 35 |
Dynamic 55 |
|
Thermal power of the boiler |
kW |
15 |
25 |
33-36 |
50-55 |
Max working pressure |
bar |
2,5 |
2,5 |
2,5 |
2,5 |
Maximum temperature |
°C |
90 |
90 |
90 |
90 |
Working temperature of the water |
°C |
80 |
80 |
80 |
80 |
Efficiency |
up to % |
74 |
74 |
75 |
75 |
Fuel - brown coals |
kcal/h |
3500-3700 |
3500-3700 |
3500-3700 |
3500-3700 |
Fuel consumption |
kg/h |
4-4,5 |
6-6,5 |
9-9,5 |
12-12,5 |
Working time per a charge |
hour |
8,5-9,5 |
8,5-9,5 |
8,5-9,5 |
8,5-9,5 |
Dimensions of water inlet / outlet - thread orifice |
inch |
1 |
1 1/4 |
1 1/4 |
1 1/2 |
Dimensions |
A mm |
544 |
570 |
628 |
780 |
B mm |
423 |
465 |
527 |
612 |
|
C mm |
731 |
749 |
857 |
990 |
|
E mm |
184 |
190 |
190 |
195 |
|
H mm |
1055 |
1170 |
1170 |
1392 |
|
L mm |
980 |
1096 |
1096 |
1250 |
|
D mm |
Ø 160 |
Ø 200 |
Ø 200 |
Ø 200 |
|
h mm |
839 |
932 |
933 |
1090 |
|
Weight |
kg |
152 |
218 |
267 |
355 |
Volume of the water jacket |
L |
72 |
90 |
112 |
165 |
LEGEND: |
||||
1 |
Return water inlet - orifice |
8 |
Thermometer up to 120°C |
|
2 |
Probe - water protection / when installed a serpentine/ |
9 |
Mechanical air thermostat |
|
3 |
Inlet- outlet serpentine |
10 |
Upper door – for fuel feeding |
|
4 |
Delivery water inlet - orifice |
11 |
Lower door – for cleaning |
|
5 |
Flue valve |
12 |
Adjustable air door - connected via a metal chain to the mechanical thermostat that regulates the draught |
|
6 |
Flue - ∅ |
|||
7 |
1/2" drainage |
13 |
Ashtray |